Home Enter Sweepstake History Submitted Stuff Contact Us
50 Years of Innovations !
June, 1958
June, 1963
May, 1969
July, 1972
June, 1973
June, 1978
January, 1983
August, 1989
March, 2005
March, 2005
August, 2006
more coming
in 2008
History
June, 1858
Natural and U.V. Black TiesJune, 1963
Metal Bard & Curved TailMay, 1969
Polypropylene Cable TiesJuly, 1972
Fluoropolymer (Tefzel)June, 1973
Heat Stabilized (105°C)June, 1978
Flame RetardantAugust, 1989
Fluoropolymer (Halar)March, 2005
UV - Heat StabilizedMarch, 2005
Extra-High Temperature (150°C)August, 2006
Detectable Cable Ties
June, 1958
Natural and U.V. Black Ties.
Problem: Lacing cord & tape were the only tools used prior to the invention of the first cable tie.
Solution: Faster, more efficient means of bundling/fastening.
Part Number: TY5, TY5X, TY8, TY8X
June, 1963
Metal Bard & Curved Tail.
Problem: No positive lock/Twisted into place.
Solution: Barb gave positive and more reliable.
Part Number: TY5M, TY25M, TY25M-2
May, 1969
Polypropylene Cable Ties.
Problem: Chemical exposure eroded nylon.
Solution: Much greater chemical resistance than nylon 6.6.
Part Number: TYP25MX
July, 1972
Fluoropolymer (Tefzel).
Problem: Heat and radiation eroded nylon.
Solution: Greater heat (302º vs 185º) and radiation resistance.
Part Number: TYZ25M
June, 1973
Heat Stabilized (105ºC).
Problem: Heat exposure softened/weakened nylon.
Solution: Greater heat (221º vs 185º) resistance.
Part Number: TYH25M
June, 1978
Flame Retardant.
Problem: Exposure to flame/Fire hazard.
Solution: Meets UL 94V-O flammability rating.
Part Number: TY25MFR
January, 1983
Nylon 12.
Problem: Nylon 66 affected by moisture containt / UV exposure.
Solution: Nylon 12 minimum effect to moisture / UV resistance.
Part Number: TYC25MX
August, 1989
Fluoropolymer (Halar).
Problem: Need for low smoke in air handling applications.
Solution: Low smoke density / UL 984V-O flammability rating.
Part Number: TYV25M
March, 2005
UV - Heat Stabilized.
Problem: Heat / UV exposure required in same product.
Solution: Greater heat (221º vs 185º) resistance / UV stabilized.
Part Number: TY25MX-A
March, 2005
Extra-High Temperature (150ºC).
Problem: Greater heat exposure than TYH product.
Solution: Greater heat (302º vs 221º) resistance.
Part Number: TYHT25M
August, 2006
Detectable Cable Ties.
Problem: Contaminants falling into food processing.
Solution: Detectable by both x-ray and magnetic scanner.
Part Number: TY25M-NDT, TY25M-PDT
more coming
in 2008
 | Home | Enter Sweepstake | History | What's New | Contact Us |  Thomas & Betts